[PDF] Boron Lined Multitube Neutron Proportional Counter Test - eBooks Review

Boron Lined Multitube Neutron Proportional Counter Test


Boron Lined Multitube Neutron Proportional Counter Test
DOWNLOAD

Download Boron Lined Multitube Neutron Proportional Counter Test PDF/ePub or read online books in Mobi eBooks. Click Download or Read Online button to get Boron Lined Multitube Neutron Proportional Counter Test book now. This website allows unlimited access to, at the time of writing, more than 1.5 million titles, including hundreds of thousands of titles in various foreign languages. If the content not found or just blank you must refresh this page



Boron Lined Multitube Neutron Proportional Counter Test


Boron Lined Multitube Neutron Proportional Counter Test
DOWNLOAD
Author :
language : en
Publisher:
Release Date : 2010

Boron Lined Multitube Neutron Proportional Counter Test written by and has been published by this book supported file pdf, txt, epub, kindle and other format this book has been release on 2010 with categories.


Radiation portal monitors used for interdiction of illicit materials at borders include highly sensitive neutron detection systems. The main reason for having neutron detection capability is to detect fission neutrons from plutonium. The currently deployed radiation portal monitors (RPMs) from Ludlum and Science Applications International Corporation (SAIC) use neutron detectors based upon 3He-filled gas proportional counters, which are the most common large neutron detector. There is a declining supply of 3He in the world, and thus, methods to reduce the use of this gas in RPMs with minimal changes to the current system designs and sensitivity to cargo-borne neutrons are being investigated. Four technologies have been identified as being currently commercially available, potential alternative neutron detectors to replace the use of 3He in RPMs. These technologies are: 1) Boron trifluoride (BF3)-filled proportional counters, 2) Boron-lined proportional counters, 3) Lithium-loaded glass fibers, and 4) Coated non-scintillating plastic fibers. In addition, a few other companies have detector technologies that might be competitive in the near term as an alternative technology. Reported here are the results of tests of a boron-lined,?multitube? proportional counter manufactured by Centronic Ltd. (Surry, U.K. and Houston, TX). This testing measured the required performance for neutron detection efficiency and gamma-ray rejection capabilities of the detector.



Boron Lined Multichamber And Conventional Neutron Proportional Counter Tests


Boron Lined Multichamber And Conventional Neutron Proportional Counter Tests
DOWNLOAD
Author :
language : en
Publisher:
Release Date : 2010

Boron Lined Multichamber And Conventional Neutron Proportional Counter Tests written by and has been published by this book supported file pdf, txt, epub, kindle and other format this book has been release on 2010 with categories.


Radiation portal monitors used for interdiction of illicit materials at borders include highly sensitive neutron detection systems. The main reason for having neutron detection capability is to detect fission neutrons from plutonium. The currently deployed radiation portal monitors (RPMs) from Ludlum and Science Applications International Corporation (SAIC) use neutron detectors based upon 3He-filled gas proportional counters, which are the most common large neutron detector. There is a declining supply of 3He in the world, and thus, methods to reduce the use of this gas in RPMs with minimal changes to the current system designs and sensitivity to cargo-borne neutrons are being investigated. Four technologies have been identified as being currently commercially available, potential alternative neutron detectors to replace the use of 3He in RPMs. These technologies are: 1) Boron trifluoride (BF3)-filled proportional counters, 2) Boron-lined proportional counters, 3) Lithium-loaded glass fibers, and 4) Coated non-scintillating plastic fibers. In addition, a few other companies have detector technologies that might be competitive in the near term as an alternative technology. Reported here are the results of tests of a boron-lined, multichamber proportional counter manufactured by LND, Inc. Also reported are results obtained with an earlier design of conventional, boron-lined, proportional counters from LND. This testing measured the required performance for neutron detection efficiency and gamma-ray rejection capabilities of the detectors.



Boron Lined Straw Tube Neutron Detector Test


Boron Lined Straw Tube Neutron Detector Test
DOWNLOAD
Author :
language : en
Publisher:
Release Date : 2010

Boron Lined Straw Tube Neutron Detector Test written by and has been published by this book supported file pdf, txt, epub, kindle and other format this book has been release on 2010 with categories.


Radiation portal monitors used for interdiction of illicit materials at borders include highly sensitive neutron detection systems. The main reason for having neutron detection capability is to detect fission neutrons from plutonium. The currently deployed radiation portal monitors (RPMs) from Ludlum and Science Applications International Corporation (SAIC) use neutron detectors based upon 3He-filled gas proportional counters, which are the most common large neutron detector. There is a declining supply of 3He in the world, and thus, methods to reduce the use of this gas in RPMs with minimal changes to the current system designs and sensitivity to cargo-borne neutrons are being investigated. Four technologies have been identified as being currently commercially available, potential alternative neutron detectors to replace the use of 3He in RPMs. Reported here are the results of tests of a boron-lined proportional counter design variation. In the testing described here, the neutron detection efficiency and gamma ray rejection capabilities of a system manufactured by Proportional Technologies, Inc, was tested.



Boron Lined Neutron Detector Measurements


Boron Lined Neutron Detector Measurements
DOWNLOAD
Author :
language : en
Publisher:
Release Date : 2009

Boron Lined Neutron Detector Measurements written by and has been published by this book supported file pdf, txt, epub, kindle and other format this book has been release on 2009 with categories.


Radiation portal monitors used for interdiction of illicit materials at borders include highly sensitive neutron detection systems. The main reason for having neutron detection capability is to detect fission neutrons from plutonium. The currently deployed radiation portal monitors (RPMs) from Ludlum and Science Applications International Corporation (SAIC) use neutron detectors based upon 3He-filled gas proportional counters, which are the most common large neutron detector. There is a declining supply of 3He in the world, and thus, methods to reduce the use of this gas in RPMs with minimal changes to the current system designs and sensitivity to cargo-borne neutrons are being investigated. Four technologies have been identified as being currently commercially available, potential alternative neutron detectors to replace the use of 3He in RPMs. Reported here are the results of tests of a newly designed boron-lined proportional counter option. This testing measured the neutron detection efficiency and gamma ray rejection capabilities of a system manufactured by Reuter Stokes.



Preliminary Testing Of A Proportional Counter For Neutron Spectroscopy With Helium 3


Preliminary Testing Of A Proportional Counter For Neutron Spectroscopy With Helium 3
DOWNLOAD
Author : John N. Green
language : en
Publisher:
Release Date : 1958

Preliminary Testing Of A Proportional Counter For Neutron Spectroscopy With Helium 3 written by John N. Green and has been published by this book supported file pdf, txt, epub, kindle and other format this book has been release on 1958 with Economics categories.




Summary Of Neutron Measurement Methods


Summary Of Neutron Measurement Methods
DOWNLOAD
Author : Herman Lunden Miller
language : en
Publisher:
Release Date : 1962

Summary Of Neutron Measurement Methods written by Herman Lunden Miller and has been published by this book supported file pdf, txt, epub, kindle and other format this book has been release on 1962 with Gamma rays categories.




A Thermal Neutron Velocity Selector And Its Application To The Measurements Of The Cross Section Of Boron


A Thermal Neutron Velocity Selector And Its Application To The Measurements Of The Cross Section Of Boron
DOWNLOAD
Author : Enrico Fermi
language : en
Publisher:
Release Date : 1947

A Thermal Neutron Velocity Selector And Its Application To The Measurements Of The Cross Section Of Boron written by Enrico Fermi and has been published by this book supported file pdf, txt, epub, kindle and other format this book has been release on 1947 with Boron categories.




Neutron Dosimetry


Neutron Dosimetry
DOWNLOAD
Author : John W. Baum
language : en
Publisher:
Release Date : 1955

Neutron Dosimetry written by John W. Baum and has been published by this book supported file pdf, txt, epub, kindle and other format this book has been release on 1955 with Drugs categories.




Evaluation Of A Boron Lined Neutron Detector


Evaluation Of A Boron Lined Neutron Detector
DOWNLOAD
Author : B. M. Van der Ende
language : en
Publisher:
Release Date : 2014

Evaluation Of A Boron Lined Neutron Detector written by B. M. Van der Ende and has been published by this book supported file pdf, txt, epub, kindle and other format this book has been release on 2014 with categories.




A Neutron Proportional Counter


A Neutron Proportional Counter
DOWNLOAD
Author : J. Breukelaar
language : en
Publisher:
Release Date : 1983

A Neutron Proportional Counter written by J. Breukelaar and has been published by this book supported file pdf, txt, epub, kindle and other format this book has been release on 1983 with Neutron counters categories.