[PDF] Analytical Studies Of The Mach Zehnder Interferometer - eBooks Review

Analytical Studies Of The Mach Zehnder Interferometer


Analytical Studies Of The Mach Zehnder Interferometer
DOWNLOAD

Download Analytical Studies Of The Mach Zehnder Interferometer PDF/ePub or read online books in Mobi eBooks. Click Download or Read Online button to get Analytical Studies Of The Mach Zehnder Interferometer book now. This website allows unlimited access to, at the time of writing, more than 1.5 million titles, including hundreds of thousands of titles in various foreign languages. If the content not found or just blank you must refresh this page





Analytical Studies Of The Mach Zehnder Interferometer


Analytical Studies Of The Mach Zehnder Interferometer
DOWNLOAD
Author : Naval Ordnance Laboratory, (White Oak, Md.)
language : en
Publisher:
Release Date : 1947

Analytical Studies Of The Mach Zehnder Interferometer written by Naval Ordnance Laboratory, (White Oak, Md.) and has been published by this book supported file pdf, txt, epub, kindle and other format this book has been release on 1947 with Interferometers categories.




Analytical Studies Of The Mach Zehnder Interferometer


Analytical Studies Of The Mach Zehnder Interferometer
DOWNLOAD
Author : Ernst H.. Winkler
language : en
Publisher:
Release Date : 1947

Analytical Studies Of The Mach Zehnder Interferometer written by Ernst H.. Winkler and has been published by this book supported file pdf, txt, epub, kindle and other format this book has been release on 1947 with Interferometers categories.




Analytical Studies Of The Mach Zehnder Interferometer


Analytical Studies Of The Mach Zehnder Interferometer
DOWNLOAD
Author : U.S. Naval Ordnance Laboratory, White Oak, Md
language : en
Publisher:
Release Date : 1950

Analytical Studies Of The Mach Zehnder Interferometer written by U.S. Naval Ordnance Laboratory, White Oak, Md and has been published by this book supported file pdf, txt, epub, kindle and other format this book has been release on 1950 with categories.




Two Meter Mach Zehnder Interferometer For Plasma Density Measurements


Two Meter Mach Zehnder Interferometer For Plasma Density Measurements
DOWNLOAD
Author : W. H. Borkenhagen
language : en
Publisher:
Release Date : 1963

Two Meter Mach Zehnder Interferometer For Plasma Density Measurements written by W. H. Borkenhagen and has been published by this book supported file pdf, txt, epub, kindle and other format this book has been release on 1963 with Interferometers categories.




Analysis Of A Mach Zehnder Interferometric Optical Modulator


Analysis Of A Mach Zehnder Interferometric Optical Modulator
DOWNLOAD
Author : Paul Leverett Stoddard
language : en
Publisher:
Release Date : 1991

Analysis Of A Mach Zehnder Interferometric Optical Modulator written by Paul Leverett Stoddard and has been published by this book supported file pdf, txt, epub, kindle and other format this book has been release on 1991 with categories.




An Interferometric Method Of Gas Analysis


An Interferometric Method Of Gas Analysis
DOWNLOAD
Author : H. Lowell Olsen
language : en
Publisher:
Release Date : 1948

An Interferometric Method Of Gas Analysis written by H. Lowell Olsen and has been published by this book supported file pdf, txt, epub, kindle and other format this book has been release on 1948 with categories.




Applications Of Mach Zehnder Interferometry To Studies On Local Deformation Of Polymers Under Photocuring


Applications Of Mach Zehnder Interferometry To Studies On Local Deformation Of Polymers Under Photocuring
DOWNLOAD
Author : Dan-Thuy Van-Pham
language : en
Publisher:
Release Date : 2017

Applications Of Mach Zehnder Interferometry To Studies On Local Deformation Of Polymers Under Photocuring written by Dan-Thuy Van-Pham and has been published by this book supported file pdf, txt, epub, kindle and other format this book has been release on 2017 with Technology categories.


A Mach-Zehnder interferometer (MZI) was built and modified to in situ monitor the deformation of polymers during the photocuring process. In this review, the working principle and method of operation of this MZI were explained together with the method of data analysis. As the examples for the utilization of this modified MZI, measurements of the deformation induced by photopolymerization was demonstrated for three different types of samples: homopolymer in the bulk state, miscible polymer blends and phase-separated polymer blends. Finally, a concluding remark is provided for the usage of MZI in polymer research.



Studies On Mass Transfer In Streamline Flow With The Mach Zehnder Interferometer


Studies On Mass Transfer In Streamline Flow With The Mach Zehnder Interferometer
DOWNLOAD
Author : Wallace Ray Wood
language : en
Publisher:
Release Date : 1953

Studies On Mass Transfer In Streamline Flow With The Mach Zehnder Interferometer written by Wallace Ray Wood and has been published by this book supported file pdf, txt, epub, kindle and other format this book has been release on 1953 with Interferometers categories.




Optimum Source Size For The Mach Zehnder Interferometer


Optimum Source Size For The Mach Zehnder Interferometer
DOWNLOAD
Author : Frederick D. Bennett
language : en
Publisher:
Release Date : 1950

Optimum Source Size For The Mach Zehnder Interferometer written by Frederick D. Bennett and has been published by this book supported file pdf, txt, epub, kindle and other format this book has been release on 1950 with categories.


A vector analytic treatment is given of the formation of undisturbed fringes by an ideal Mach-Zehnder interferometer with an extended source. The path difference of two interfering rays at an arbitrary point in the field is found to depend in a simple way upon the source point from which the rays originate, the field point examined, and a dyadic which is a function of the unit normals to the last mirror and divider plate of the interferometer. The fringe clarity condition that all pairs of interfering rays reaching the field point have path differences within a specified range is developed in the form of an inequality. Analysis of this fundamental inequality shows that all admissible area sources must be areas enclosed between two conics in the source plane. For fringes perpendicular to the plane of centers of the interferometer elements, the optimum source is a circle with radius inversely proportional to the square root of the number of clear fringes desired. This result holds for all interferometers of parellelogram planform. For fringes parallel to the plane of centers, each interferometer orientation presents a special case. The optimum source area is obtained for two of these, viz., the 45 and 30 deg interferometers. (Author).



Development And Analysis Of Photonic Crystal Fiber Mach Zehnder Interferometer For Highly Sensitive Detection And Quantification Of Gases


Development And Analysis Of Photonic Crystal Fiber Mach Zehnder Interferometer For Highly Sensitive Detection And Quantification Of Gases
DOWNLOAD
Author : Kaveh Nazeri
language : en
Publisher:
Release Date : 2020

Development And Analysis Of Photonic Crystal Fiber Mach Zehnder Interferometer For Highly Sensitive Detection And Quantification Of Gases written by Kaveh Nazeri and has been published by this book supported file pdf, txt, epub, kindle and other format this book has been release on 2020 with categories.


Gas sensing is essential for safety and maintenance operations in many industries, including power generation, petrochemical, capture and storage technologies, and the food-processing sector. The properties of fiber-optic sensors make them a superior choice for environmental monitoring applications, especially in extreme conditions, and particularly when compared against conventional electro-optical sensors. Their advantageous properties include immunity to electromagnetic radiation, high temperature durability, high sensitivity and the ability for high resolution detection, as well as multifunctional sensing capabilities such as temperature, humidity, pressure, strain, and corrosion. Among different types of interferometers, Mach-Zehnder Interferometers (MZI) have received significant attention because they are robust, compact, and have high levels of precision. In this dissertation, we present an in-line and compact MZI point sensor designed for sensing refractive index. In comparison with various types of interferometers, fiber MZI based RI sensing was selected based on its enhanced sensitivity and fabrication simplicity. The MZI sensor is developed using photonic crystal fiber and demonstrated for high sensitivity detection and measurement of pure gases. The transmission spectrum of MZI sensors is formed by interference between the cladding and core modes. To construct the device, the sensing element fiber was placed and aligned between two single-mode fibers with air gaps at each side. Two linear-translation micro stages were used to accurately differ and adjust gap lengths from 0 to 5mm. Great measurement repeatability was shown in the cyclic test for the detection of various gases such as methane and helium. A high RI measurement resolution of 2.1 E-7 and a sensitivity of 4629 nm/RIU was achieved, which is among the highest reported. Results show that the sensitivity of the fabricated MZI increases from 3000 nm/RIU to 4600 nm/RIU when the length of the sensing element fiber decreases from 5 mm to 3.3 mm. Furthermore, the device was packaged to demonstrate the laboratory-scale monitoring, as well as leakage detection of different concentrations of CO2 in both subsurface soil and aqueous environments. Two water resistant but gas permeable membranes were used to package the sensor, to achieve a good balance of CO2 permeability and water resistance. The experimental study of this work reveals the great potential of the fiber-optic approach for environmental monitoring of CO2. This study also explores other potential applications. Three types of sensors were fabricated using the proposed configuration employing 4 mm stub of (i) solid core Photonic Crystal Fiber (PCF), (ii) 10 μm Hollow core PCF (HC-PCF), and (iii) 20 μm HC-PCF as the sensing elements. We compared the performance of these sensors for detecting and measuring the quantity of gas present. As the transmission signals correspond to the frequency components in the sensor's Fast Fourier Transform (FFT) spectrum, the effect of gap distance on the number and amplitude distribution of the modes was examined in an effort to optimize the design elements. The MZI sensors are highly sensitive to low percentages of CH4 and CO2, making them suitable for greenhouse gas measurement.