[PDF] Finding Of No Significant Impact For Casper Dave Johnston 230 Kv Transmission Line Project Converse And Natrona Counties Wyoming - eBooks Review

Finding Of No Significant Impact For Casper Dave Johnston 230 Kv Transmission Line Project Converse And Natrona Counties Wyoming


Finding Of No Significant Impact For Casper Dave Johnston 230 Kv Transmission Line Project Converse And Natrona Counties Wyoming
DOWNLOAD

Download Finding Of No Significant Impact For Casper Dave Johnston 230 Kv Transmission Line Project Converse And Natrona Counties Wyoming PDF/ePub or read online books in Mobi eBooks. Click Download or Read Online button to get Finding Of No Significant Impact For Casper Dave Johnston 230 Kv Transmission Line Project Converse And Natrona Counties Wyoming book now. This website allows unlimited access to, at the time of writing, more than 1.5 million titles, including hundreds of thousands of titles in various foreign languages. If the content not found or just blank you must refresh this page





Finding Of No Significant Impact For Casper Dave Johnston 230 Kv Transmission Line Project Converse And Natrona Counties Wyoming


Finding Of No Significant Impact For Casper Dave Johnston 230 Kv Transmission Line Project Converse And Natrona Counties Wyoming
DOWNLOAD
Author : United States. Department of Energy
language : en
Publisher:
Release Date : 1986

Finding Of No Significant Impact For Casper Dave Johnston 230 Kv Transmission Line Project Converse And Natrona Counties Wyoming written by United States. Department of Energy and has been published by this book supported file pdf, txt, epub, kindle and other format this book has been release on 1986 with Converse County (Wyo.) categories.




Casper To Dave Johnson 230 Kv Transmission Line Project


Casper To Dave Johnson 230 Kv Transmission Line Project
DOWNLOAD
Author :
language : en
Publisher:
Release Date : 1986

Casper To Dave Johnson 230 Kv Transmission Line Project written by and has been published by this book supported file pdf, txt, epub, kindle and other format this book has been release on 1986 with Electric lines categories.




Casper To Dave Johnston 230 Kv Transmission Line Project


Casper To Dave Johnston 230 Kv Transmission Line Project
DOWNLOAD
Author : United States. Department of Energy
language : en
Publisher:
Release Date : 1986

Casper To Dave Johnston 230 Kv Transmission Line Project written by United States. Department of Energy and has been published by this book supported file pdf, txt, epub, kindle and other format this book has been release on 1986 with Converse County (Wyo.) categories.




Casper To Dave Johnson 230 Kv Transmission Line Project


Casper To Dave Johnson 230 Kv Transmission Line Project
DOWNLOAD
Author :
language : en
Publisher:
Release Date : 1986

Casper To Dave Johnson 230 Kv Transmission Line Project written by and has been published by this book supported file pdf, txt, epub, kindle and other format this book has been release on 1986 with Electric lines categories.




Thermopolis Alcova Casper Transmission Line Project Wyoming


Thermopolis Alcova Casper Transmission Line Project Wyoming
DOWNLOAD
Author :
language : en
Publisher:
Release Date : 1983

Thermopolis Alcova Casper Transmission Line Project Wyoming written by and has been published by this book supported file pdf, txt, epub, kindle and other format this book has been release on 1983 with Electric lines categories.


This EIS assesses the environmental effects of constructing 152.1 miles of 230-kV or 230/345-kV transmission line between Thermopolis and Alcova, and between Alcova and Casper. Approximately 136.1 miles of the new 230-kV or 230/345-kV line will either replace two existing but deteriorated 69-kV lines or parallel an existing 115-kV line. The remaining 16.0 miles of line will be constructed on a new corridor. In addition, approximately 50.0 miles of 69-kV line will be reconstructed at 69/115-kV between Arminto and Casper. Other minor elements of the project include construction of short 34.5-kV and 69/115-kV connecting lines, and a new substation near Alcova. The purpose of the project is to bring the regional transmission system into compliance with National Electric Reliability Council criteria and to reduce energy losses associated with overloading of the existing system. Alternatives assessed include no action, delay, reduction in the quality of electrical service, alternative transmission technologies, alternative design, and alternative routes. Significant impacts include soil disturbance and increased erosion, potential disturbance of sensitive habitats for sage grouse, bald eagles and raptors, and increased visual impacts created by the replacement of small, wood structures with larger transmission structures.



Thermopolis Alcova Casper Transmission Line Project Wyoming


Thermopolis Alcova Casper Transmission Line Project Wyoming
DOWNLOAD
Author :
language : en
Publisher:
Release Date : 1983

Thermopolis Alcova Casper Transmission Line Project Wyoming written by and has been published by this book supported file pdf, txt, epub, kindle and other format this book has been release on 1983 with Electric lines categories.


This EIS assesses the environmental effects of constructing 152.1 miles of 230-kV or 230/345-kV transmission line between Thermopolis and Alcova, and between Alcova and Casper. Approximately 136.1 miles of the new 230-kV or 230/345-kV line will either replace two existing but deteriorated 69-kV lines or parallel an existing 115-kV line. The remaining 16.0 miles of line will be constructed on a new corridor. In addition, approximately 50.0 miles of 69-kV line will be reconstructed at 69/115-kV between Arminto and Casper. Other minor elements of the project include construction of short 34.5-kV and 69/115-kV connecting lines, and a new substation near Alcova. The purpose of the project is to bring the regional transmission system into compliance with National Electric Reliability Council criteria and to reduce energy losses associated with overloading of the existing system. Alternatives assessed include no action, delay, reduction in the quality of electrical service, alternative transmission technologies, alternative design, and alternative routes. Significant impacts include soil disturbance and increased erosion, potential disturbance of sensitive habitats for sage grouse, bald eagles and raptors, and increased visual impacts created by the replacement of small, wood structures with larger transmission structures.



Environmental Assessment And Finding Of No Significant Impact


Environmental Assessment And Finding Of No Significant Impact
DOWNLOAD
Author :
language : en
Publisher:
Release Date : 2003

Environmental Assessment And Finding Of No Significant Impact written by and has been published by this book supported file pdf, txt, epub, kindle and other format this book has been release on 2003 with categories.


The U.S. Highway 93 (U.S. 93) Hoover Dam Bypass Project calls for the U.S. Department of Energy (DOE) Western Area Power Administration (Western) to remove its Arizona and Nevada (A & N) Switchyard. As a result of this action, Western must reconfigure its existing electrical transmission system in the Hoover Dam area. Western proposes to double-circuit a portion of the Hoover-Mead No. 5 and No. 7 230-kV Transmission Lines with the Henderson-Mead No. 1 Transmission Line (see Figure 1-1). Double-circuiting is the placement of two separate electrical circuits, typically in the form of three separate conductors or bundles of conductors, on the same set of transmission line structures. The old Henderson-Hoover 230-kV Transmission Line would become the new Henderson-Mead No. 1 and would extend approximately eight miles to connect with the Mead Substation. Western owns, operates, and maintains the Hoover-Mead No. 5 and No. 7, and Henderson-Hoover electrical power transmission lines. Additionally, approximately 0.25 miles of new right-of-way (ROW) would be needed for the Henderson-Mead No. 1 when it transfers from double-circuiting with the Hoover-Mead No. 7 to the Hoover-Mead No. 5 at the Boulder City Tap. The proposed project would also involve a new transmission line ROW and structures where the Henderson-Mead No. 1 will split from the Hoover-Mead No. 5 and enter the northeast corner of the Mead Substation. Lastly, Western has proposed adding fiber optic overhead ground wire from the Hoover Power Plant to the Mead Substation on to the Henderson-Mead No. 1, Hoover-Mead No. 5 and No. 7 Transmission Lines. The proposed project includes replacing existing transmission line tower structures, installing new structures, and adding new electrical conductors and fiber optic cables. As a consequence of these activities, ground disturbance may result from grading areas for structure placement, constructing new roads, improving existing roads for vehicle and equipment access, and from installing structures, conductors, and fiber optic cables. Project construction activities would be conducted within the existing 200-foot transmission line ROW and 50-foot access road ROW, although new spur access roads could occur outside of existing ROWs. As lead Federal agency for this action under National Environmental Policy Act (NEPA), Western must ensure that adverse environmental effects on Federal and non-Federal lands and resources are avoided or minimized. This Environmental Assessment (EA) is intended to be a concise public document that assesses the probable and known impacts to the environment from Western's Proposed Action and alternatives, and reaches a conclusion about the significance of the impacts. This EA was prepared in compliance with NEPA regulations published by the Council on Environmental Quality (40 CFR 1500-1508) and implementing procedures of the Department of Energy (10 CFR 1021).



Trait Pass Entre Mm Les Pr V T Des Marchands Et Chevins De Cette Ville De Lyon Mm Les Recteurs Et Administrateurs De L Aum Ne G N Rale Et H Tel Dieu Et Mm Les Recteurs De La Maison Des Recluses Le 6 Octobre 1702 Par Lequel Il A T Convenu Que L On Fera Renfermer Les Maquerelles Et Coureuses De Profession


Trait Pass Entre Mm Les Pr V T Des Marchands Et Chevins De Cette Ville De Lyon Mm Les Recteurs Et Administrateurs De L Aum Ne G N Rale Et H Tel Dieu Et Mm Les Recteurs De La Maison Des Recluses Le 6 Octobre 1702 Par Lequel Il A T Convenu Que L On Fera Renfermer Les Maquerelles Et Coureuses De Profession
DOWNLOAD
Author :
language : en
Publisher:
Release Date : 1708

Trait Pass Entre Mm Les Pr V T Des Marchands Et Chevins De Cette Ville De Lyon Mm Les Recteurs Et Administrateurs De L Aum Ne G N Rale Et H Tel Dieu Et Mm Les Recteurs De La Maison Des Recluses Le 6 Octobre 1702 Par Lequel Il A T Convenu Que L On Fera Renfermer Les Maquerelles Et Coureuses De Profession written by and has been published by this book supported file pdf, txt, epub, kindle and other format this book has been release on 1708 with categories.




Finding Of No Significant Impact Warren Air Force Base 115 Kv Transmission Line Project Cheyenne Wyoming


Finding Of No Significant Impact Warren Air Force Base 115 Kv Transmission Line Project Cheyenne Wyoming
DOWNLOAD
Author : United States. Western Area Power Administration
language : en
Publisher:
Release Date : 1986

Finding Of No Significant Impact Warren Air Force Base 115 Kv Transmission Line Project Cheyenne Wyoming written by United States. Western Area Power Administration and has been published by this book supported file pdf, txt, epub, kindle and other format this book has been release on 1986 with Electric substations categories.




Carter Mountain Thermopolis 230 Kv Transmission Line Project Hot Springs County Wyoming


Carter Mountain Thermopolis 230 Kv Transmission Line Project Hot Springs County Wyoming
DOWNLOAD
Author : United States. Western Area Power Administration
language : en
Publisher:
Release Date : 1992

Carter Mountain Thermopolis 230 Kv Transmission Line Project Hot Springs County Wyoming written by United States. Western Area Power Administration and has been published by this book supported file pdf, txt, epub, kindle and other format this book has been release on 1992 with Electric lines categories.