Ibm Storage Networking San768c 6 Product Guide

DOWNLOAD
Download Ibm Storage Networking San768c 6 Product Guide PDF/ePub or read online books in Mobi eBooks. Click Download or Read Online button to get Ibm Storage Networking San768c 6 Product Guide book now. This website allows unlimited access to, at the time of writing, more than 1.5 million titles, including hundreds of thousands of titles in various foreign languages. If the content not found or just blank you must refresh this page
Ibm Storage Networking San768c 6 Product Guide
DOWNLOAD
Author : Jon Tate
language : en
Publisher: IBM Redbooks
Release Date : 2018-12-04
Ibm Storage Networking San768c 6 Product Guide written by Jon Tate and has been published by IBM Redbooks this book supported file pdf, txt, epub, kindle and other format this book has been release on 2018-12-04 with Computers categories.
This IBM® Redbooks® Product Guide describes the IBM Storage Networking SAN768C-6. IBM Storage Networking SAN768C-6 has the industry's highest port density for a storage area network (SAN) director and features 768 line-rate 32 gigabits per second (Gbps) or 16 Gbps Fibre Channel ports. Designed to support multiprotocol workloads, IBM Storage Networking SAN768C-6 enables SAN consolidation and collapsed-core solutions for large enterprises, which reduces the number of managed switches and leads to easy-to-manage deployments. IBM Storage Networking SAN768C-6 supports the 48-Port 32 Gbps Fibre Channel Switching Module, the 48-Port 16 Gbps Fibre Channel Switching Module, the 48-port 10 Gbps FCoE Switching Module, the 24-port 40 Gbps FCoE switching module, and the 24/10-port SAN Extension Module. By reducing the number of front-panel ports that are used on inter-switch links (ISLs), it also offers room for future growth. IBM Storage Networking SAN768C-6 addresses the mounting storage requirements of today's large virtualized data centers. As a director-class SAN switch, IBM Storage Networking SAN768C-6 uses the same operating system and management interface as other IBM data center switches. It brings intelligent capabilities to a high-performance, protocol-independent switch fabric, and delivers uncompromising availability, security, scalability, simplified management, and the flexibility to integrate new technologies. You can use IBM Storage Networking SAN768C-6 to transparently deploy unified fabrics with Fibre Channel and Fibre Channel over Ethernet (FCoE) connectivity to achieve low total cost of ownership (TCO). For mission-critical enterprise storage networks that require secure, robust, cost-effective business-continuance services, the FCIP extension module is designed to deliver outstanding SAN extension performance, reducing latency for disk and tape operations with FCIP acceleration features, including FCIP write acceleration and FCIP tape write and read acceleration.
Ibm Storage Networking San768c 6 Product Guide
DOWNLOAD
Author : Jon Tate
language : en
Publisher:
Release Date : 2018
Ibm Storage Networking San768c 6 Product Guide written by Jon Tate and has been published by this book supported file pdf, txt, epub, kindle and other format this book has been release on 2018 with categories.
This IBM® Redbooks® Product Guide describes the IBM Storage Networking SAN768C-6. IBM Storage Networking SAN768C-6 has the industry's highest port density for a storage area network (SAN) director and features 768 line-rate 32 gigabits per second (Gbps) or 16 Gbps Fibre Channel ports. Designed to support multiprotocol workloads, IBM Storage Networking SAN768C-6 enables SAN consolidation and collapsed-core solutions for large enterprises, which reduces the number of managed switches and leads to easy-to-manage deployments. IBM Storage Networking SAN768C-6 supports the 48-Port 32 Gbps Fibre Channel Switching Module, the 48-Port 16 Gbps Fibre Channel Switching Module, the 48-port 10 Gbps FCoE Switching Module, the 24-port 40 Gbps FCoE switching module, and the 24/10-port SAN Extension Module. By reducing the number of front-panel ports that are used on inter-switch links (ISLs), it also offers room for future growth. IBM Storage Networking SAN768C-6 addresses the mounting storage requirements of today's large virtualized data centers. As a director-class SAN switch, IBM Storage Networking SAN768C-6 uses the same operating system and management interface as other IBM data center switches. It brings intelligent capabilities to a high-performance, protocol-independent switch fabric, and delivers uncompromising availability, security, scalability, simplified management, and the flexibility to integrate new technologies. You can use IBM Storage Networking SAN768C-6 to transparently deploy unified fabrics with Fibre Channel and Fibre Channel over Ethernet (FCoE) connectivity to achieve low total cost of ownership (TCO). For mission-critical enterprise storage networks that require secure, robust, cost-effective business-continuance services, the FCIP extension module is designed to deliver outstanding SAN extension performance, reducing latency for disk and tape operations with FCIP acceleration features, including FCIP write acceleration and FCIP tape write and read acceleration.
Ibm Storage Networking San768c 6 Product Guide
DOWNLOAD
Author :
language : en
Publisher:
Release Date : 2018
Ibm Storage Networking San768c 6 Product Guide written by and has been published by this book supported file pdf, txt, epub, kindle and other format this book has been release on 2018 with Information storage and retrieval systems categories.
Ibm Power System E980 Technical Overview And Introduction
DOWNLOAD
Author : Scott Vetter
language : en
Publisher: IBM Redbooks
Release Date : 2023-06-28
Ibm Power System E980 Technical Overview And Introduction written by Scott Vetter and has been published by IBM Redbooks this book supported file pdf, txt, epub, kindle and other format this book has been release on 2023-06-28 with Computers categories.
This IBM® RedpaperTM publication provides a broad understanding of a new architecture of the IBM Power System E980 (9080-M9S) server that supports IBM AIX®, IBM i, and Linux operating systems (OSes). The objective of this paper is to introduce the major innovative Power E980 offerings and relevant functions: The IBM POWER9TM processor, which is available at frequencies of 3.55 - 4.0 GHz. Significantly strengthened cores and larger caches. Supports up to 64 TB memory. Integrated I/O subsystem and hot-pluggable Peripheral Component Interconnect Express (PCIe) Gen4 slots, double the bandwidth of Gen3 I/O slots. Supports EXP12SX and ESP24SX external disk drawers, which have 12 Gb SAS interfaces and double the existing EXP24S drawer bandwidth. New IBM EnergyScaleTM technology offers new variable processor frequency modes that provide a significant performance boost beyond the static nominal frequency. This publication is for professionals who want to acquire a better understanding of IBM Power SystemsTM products. The intended audience includes the following roles: Clients Sales and marketing professionals Technical support professionals IBM Business Partners Independent software vendors (ISVs) This paper expands the current set of IBM Power Systems documentation by providing a desktop reference that offers a detailed technical description of the Power E980 server. This paper does not replace the current marketing materials and configuration tools. It is intended as an extra source of information that, together with existing sources, can be used to enhance your knowledge of IBM server solutions.
Ibm Storage Networking C Type Ficon Implementation Guide
DOWNLOAD
Author : William White
language : en
Publisher: IBM Redbooks
Release Date : 2022-01-11
Ibm Storage Networking C Type Ficon Implementation Guide written by William White and has been published by IBM Redbooks this book supported file pdf, txt, epub, kindle and other format this book has been release on 2022-01-11 with Computers categories.
The next-generation IBM® c-type Directors and switches for IBM Storage Networking provides high-speed Fibre Channel (FC) and IBM Fibre Connection (IBM FICON®) connectivity from the IBM Z® platform to the storage area network (SAN) core. It enables enterprises to rapidly deploy high-density virtualized servers with the dual benefit of higher bandwidth and consolidation. This IBM Redpaper Redbooks publication helps administrators understand how to implement or migrate to an IBM c-type SAN environment. It provides an overview of the key hardware and software products, and it explains how to install, configure, monitor, tune, and troubleshoot your SAN environment.
Ibm Storage Networking San24b 6 Switch
DOWNLOAD
Author : Ernest A. Keenan
language : en
Publisher: IBM Redbooks
Release Date : 2018-05-23
Ibm Storage Networking San24b 6 Switch written by Ernest A. Keenan and has been published by IBM Redbooks this book supported file pdf, txt, epub, kindle and other format this book has been release on 2018-05-23 with Computers categories.
This IBM® Redbooks® product guide describes the IBM Storage Networking SAN24B-6 switch. Explosive data growth, coupled with user expectations of unlimited access from anywhere, at any time, is pushing storage environments to the limit. To meet these dynamic business demands, the network must evolve to improve speed, increase efficiency, and reduce costs. Legacy infrastructures were not designed to support the performance requirements of flash-based storage technology. A new approach to storage networking is required to unlock the full capabilities of all-flash arrays. By treating the network as a strategic part of a storage environment, organizations can maximize their productivity and efficiency, even as they rapidly grow their environments. The IBM Storage Networking SAN24B-6 switch provides exceptional value in an entry-level switch, combining high-performance capabilities of 4, 8, 16, and 32 Gbps, point-and-click simplicity, and enterprise-class functionality. The port speed capability is dependent on the transceiver installed. SAN24B-6 provides small to midsized data centers with low-cost access to industry-leading Gen 5 and Gen 6 Fibre Channel technology and the ability to start small and grow on demand from 8 to 24 ports to support an evolving storage environment. In addition, SAN24B-6 is easy to use and install, with a point-and-click user interface that simplifies deployment and saves time.
Ibm Storage Networking San512b 6 And San256b 6 Directors
DOWNLOAD
Author : Megan Gilge
language : en
Publisher: IBM Redbooks
Release Date : 2018-03-13
Ibm Storage Networking San512b 6 And San256b 6 Directors written by Megan Gilge and has been published by IBM Redbooks this book supported file pdf, txt, epub, kindle and other format this book has been release on 2018-03-13 with Computers categories.
This IBM® Redbooks® product guide describes the IBM Storage Networking SAN512B-6 (8961-F08) and SAN256B-6 (8961-F04) directors and the IBM b-type Gen 6 Extension Blade (FC 3892, 3893). Digital transformation is pushing mission-critical storage environments to the limit, with users expecting data to be accessible from anywhere, at any time, on any device. Faced with exponential data growth, the network must evolve to enable businesses to thrive in this new era. A new approach to storage networking is needed to enable databases, virtual servers, desktops, and critical applications, and to unlock the full capabilities of flash. By treating the network as a strategic part of a storage environment, organizations can maximize their productivity and efficiency even as they rapidly scale their environments. IBM Storage Networking SAN512B-6 and SAN256B-6 directors with Fabric Vision technology are modular building blocks that combine innovative hardware, software, and built-in instrumentation to ensure high levels of operational stability and redefine application performance. Fabric Vision technology enhances visibility into the health of storage environments, delivering greater control and insight to quickly identify problems and achieve critical service level agreements (SLAs). Breakthrough 32 Gbps performance shatters application performance barriers and provides support for more than 1 billion input/output operations per second (IOPS) for flash-based storage workloads while 128 Gbps UltraScale inter-chassis links enable simplified, high-bandwidth scalability between directors.
Ibm Storage Networking San64b 6 Switch
DOWNLOAD
Author : Megan Gilge
language : en
Publisher: IBM Redbooks
Release Date : 2017-07-24
Ibm Storage Networking San64b 6 Switch written by Megan Gilge and has been published by IBM Redbooks this book supported file pdf, txt, epub, kindle and other format this book has been release on 2017-07-24 with Computers categories.
This IBM® Redbooks® product guide describes the IBM Storage Networking SAN64B-6 switch. cloud infrastructures and growing flash-based storage environments by delivering market-leading Gen 6 Fibre Channel technology and capabilities. SAN64B-6 delivers unmatched 32/128 gigabits per second (Gbps) performance, industry-leading port density, and built-in instrumentation to accelerates data access, drive always-on business, and support data center consolidation in small to large-scale enterprise infrastructures.
Ibm Storage Networking San512b 6 And San256b 6 Directors
DOWNLOAD
Author : Megan Gilge
language : en
Publisher:
Release Date : 2018
Ibm Storage Networking San512b 6 And San256b 6 Directors written by Megan Gilge and has been published by this book supported file pdf, txt, epub, kindle and other format this book has been release on 2018 with Information storage and retrieval systems categories.