R Duction Des Ondulations De Couple D Une Machine Synchrone R Luctance Variable

DOWNLOAD
Download R Duction Des Ondulations De Couple D Une Machine Synchrone R Luctance Variable PDF/ePub or read online books in Mobi eBooks. Click Download or Read Online button to get R Duction Des Ondulations De Couple D Une Machine Synchrone R Luctance Variable book now. This website allows unlimited access to, at the time of writing, more than 1.5 million titles, including hundreds of thousands of titles in various foreign languages. If the content not found or just blank you must refresh this page
Control Of Non Conventional Synchronous Motors
DOWNLOAD
Author : Jean-Paul Louis
language : en
Publisher: John Wiley & Sons
Release Date : 2013-02-04
Control Of Non Conventional Synchronous Motors written by Jean-Paul Louis and has been published by John Wiley & Sons this book supported file pdf, txt, epub, kindle and other format this book has been release on 2013-02-04 with Technology & Engineering categories.
Classical synchronous motors are the most effective device to drive industrial production systems and robots with precision and rapidity. However, numerous applications require efficient controls in non-conventional situations. Firstly, this is the case with synchronous motors supplied by thyristor line-commutated inverters, or with synchronous motors with faults on one or several phases. Secondly, many drive systems use non-conventional motors such as polyphase (more than three phases) synchronous motors, synchronous motors with double excitation, permanent magnet linear synchronous motors, synchronous and switched reluctance motors, stepping motors and piezoelectric motors. This book presents efficient controls to improve the use of these non-conventional motors. Contents 1. Self-controlled Synchronous Motor: Principles of Function and Simplified Control Model, Francis Labrique and François Baudart. 2. Self-controlled Synchronous Motor: Dynamic Model Including the Behavior of Damper Windings and Commutation Overlap, Ernest Matagne. 3. Synchronous Machines in Degraded Mode, Damien Flieller, Ngac Ky Nguyen, Hervé Schwab and Guy Sturtzer. 4. Control of the Double-star Synchronous Machine Supplied by PWM Inverters, Mohamed Fouad Benkhoris. 5. Vectorial Modeling and Control of Multiphase Machines with Non-salient Poles Supplied by an Inverter, Xavier Kestelyn and Éric Semail. 6. Hybrid Excitation Synchronous Machines, Nicolas Patin and Lionel Vido. 7. Advanced Control of the Linear Synchronous Motor, Ghislain Remy and Pierre-Jean Barre. 8. Variable Reluctance Machines: Modeling and Control, Mickael Hilairet, Thierry Lubin and Abdelmounaïm Tounzi. 9. Control of the Stepping Motor, Bruno Robert and Moez Feki . 10. Control of Piezoelectric Actuators, Frédéric Giraud and Betty Lemaire-Semail.
R Duction Des Ondulations De Couple D Une Machine Synchrone R Luctance Variable
DOWNLOAD
Author : Mohand Hamiti
language : fr
Publisher:
Release Date : 2009
R Duction Des Ondulations De Couple D Une Machine Synchrone R Luctance Variable written by Mohand Hamiti and has been published by this book supported file pdf, txt, epub, kindle and other format this book has been release on 2009 with categories.
Ce travail porte sur la modélisation et la commande de la machine synchrone à réluctance variable, l'objectif étant de réduire les ondulations de couple. La méthodologie adoptée consiste à agir à la fois sur la structure de la machine et sur ses courants d'alimentation. Un état de l'art des techniques de réduction des ondulations de couple dans les machines électriques est d'abord dressé. Un modèle électromagnétique qui tient compte des harmoniques d'espace, basé sur l'approche par les fonctions de bobinage, est ensuite élaboré dans le but de caractériser et de quantifier les ondulations de couple. La pertinence du modèle est faite à travers la confrontation avec des résultats obtenus par calcul de champ par éléments finis. Ce modèle est alors utilisé pour l'optimisation des paramètres géométriques de la machine. Il a conduit à la définition d'un prototype de machine optimisée au sens du maximum de couple moyen et du minimum d'ondulations de couple. La deuxième partie de ce travail porte sur la commande de la machine en vue de compenser les ondulations de couple. Pour les simulations dynamiques de la machine pilotée par un onduleur de tension à commande vectorielle, le modèle élaboré demandant des temps de calcul raisonnables est utilisé sans difficulté particulière. Deux méthodes de compensation des ondulations de couple sont ensuite proposées. La première consiste à déterminer les courants qui produisent un couple constant en optimisant un autre critère tel que les pertes Joule ou le facteur de puissance. Une méthode de calcul systématique de ces courants est élaborée en utilisant les multiplicateurs de Lagrange. La deuxième méthode consiste à estimer en temps réel le couple résistant, puis à injecter un courant supplémentaire dans la boucle de régulation du couple. Les simulations numériques des deux méthodes ont donné des résultats probants. La validation expérimentale des calculs est effectuée sur un prototype de machine que nous avons calculé et réalisé. Les résultats des calculs, comparés aux mesures effectuées, sont satisfaisants.
Minimisation De L Ondulation De Couple Des Machines Reluctance Variable Double Saillance Influence Des Caract Ristiques De La Machine Et Des Limites De L Onduleur
DOWNLOAD
Author : Jean-Yves Le Chenadec
language : fr
Publisher:
Release Date : 1993
Minimisation De L Ondulation De Couple Des Machines Reluctance Variable Double Saillance Influence Des Caract Ristiques De La Machine Et Des Limites De L Onduleur written by Jean-Yves Le Chenadec and has been published by this book supported file pdf, txt, epub, kindle and other format this book has been release on 1993 with categories.
Les nombreux avantages des machines a reluctance variable expliquent le développement de leur utilisation, principalement pour des applications a fortes contraintes économiques ou en milieu difficile. Malheureusement, de part sa structure, ce type de moteur présente un couple instantané naturellement pulsatoire. Nous avons recherche un mode de commande permettant d'annuler -théoriquement- l'ondulation du couple polyphasé instantané, en produisant une forme d'onde de couple monophase trapézoïdale. Après avoir défini des coefficients de dimensionnement permettant de caractériser le rapport puissance silicium du convertisseur/puissance mécanique de la machine, nous avons optimise les formes d'onde de courant d'alimentation et chiffre l'influence de la forme de la caractéristique magnétique de la machine (et donc de sa structure) sur ces coefficients. Dans un deuxième temps, nous avons cherche qu'elle était l'influence des limitations -en tension- du convertisseur statique de la machine sur la forme du couple. En effet, ces limitations ne permettront pas d'injecter les formes d'onde de courant optimale, des que la vitesse augmente. Afin de valider le mode d'alimentation que nous avons utilise dans nos calculs, nous avons recherche, pour une machine existante, des lois de commande permettant de minimiser les pulsations du couple polyphasé. Ces lois de commande ont été testées sur un banc d'essai, l'ensemble des boucles de contrôle étant confié à un processeur de traitement du signal. Afin de vérifier les taux d'ondulation de couple calcules, nous avons utilise un système de mesure direct du couple instantané fourni par la machine. Nous avons alors obtenu, à basse vitesse, des taux d'ondulation de couple tout a fait satisfaisants
Compensation Active Des Ondulations De Couple D Un Moteur Synchrone Aimants Permanents
DOWNLOAD
Author : Abdoul Ousmane Ndiaye
language : fr
Publisher:
Release Date : 2002
Compensation Active Des Ondulations De Couple D Un Moteur Synchrone Aimants Permanents written by Abdoul Ousmane Ndiaye and has been published by this book supported file pdf, txt, epub, kindle and other format this book has been release on 2002 with categories.
Le travail effectué dans ce mémoire présente une méthode de compression des ondulations de couple d'un moteur synchrone à aimants permanents sans pièces polaires. L'objectif est l'amélioration de la qualité de la conversion électromécanique en minimisant les ondulations de couple et les vibrations. Le mémoire commence par une présentation des caractéristiques de couple du moteur synchrone étudié et les différentes causes des ondulations de son couple. Dans le deuxième chapitre, nous avons développé une méthode permettant, à partir du développement harmonique de la force électromotrice d'un moteur asynchrone à aimants sans pièces polaires, de calculer un nombre minimal d'harmoniques de courant permettant de compenser les ondulations de couple tout en optimisant le rendement. Les troisième et quatrième chapitres présentent le banc d'essai et l'étude expérimentale des vibrations. Le banc permet d'une part d'imposer différentes formes d'ondes de courant au moteur asynchrone à l'aide d'un système de contrôle et de commande réalisés avec l'outil dSPACE et d'autre part de relever le comportement vibratoire de l'ensemble du système (banc-moteur).
Contribution A L Etude De L Alimentation Des Machines Electriques De Fortes Puissances Minimisation Des Ondulations De Couple Lors De L Alimentation Par Cycloconvertisseur
DOWNLOAD
Author : JAMEL.. BENDJOUA
language : fr
Publisher:
Release Date : 1995
Contribution A L Etude De L Alimentation Des Machines Electriques De Fortes Puissances Minimisation Des Ondulations De Couple Lors De L Alimentation Par Cycloconvertisseur written by JAMEL.. BENDJOUA and has been published by this book supported file pdf, txt, epub, kindle and other format this book has been release on 1995 with categories.
CE TRAVAIL PORTE SUR LA MODELISATION, LA SIMULATION, LA COMMANDE DU SYSTEME CYCLOCONVERTISSEUR-MACHINE SYNCHRONE ET ASYNCHRONE ET DE LA COMPARAISON DE LEURS PERFORMANCES EN TERME D'ONDULATION DE COUPLE ELECTROMAGNETIQUE. ON MONTRE QUE LA MACHINE SYNCHRONE PERMET, EN STATIQUE, D'AVOIR UN COUPLE MOINS ONDULE. PAR CONTRE, LA MACHINE ASYNCHRONE PRESENTE UN MEILLEUR COMPORTEMENT DYNAMIQUE LORS DU DEMARRAGE. AFIN DE LIMITER LES HARMONIQUES PROVOQUES PAR LE TEMPS MORT DE SECURITE, UNE DEUXIEME HORLOGE PERMETTANT D'IMPOSER LA DUREE DU PALIER NUL A UNE VALEUR FIXE EST PROPOSEE. ENFIN, DANS LE BUT DE REDUIRE LES ONDULATIONS DU COUPLE, UNE MODIFICATION DE LA STRUCTURE DU CYCLOCONVERTISSEUR EN AJOUTANT SIX THYRISTORS DE ROUE LIBRE EST ETUDIEE. CETTE MODIFICATION A PERMIS DE REDUIRE, D'UNE FACON IMPORTANTE, LES ONDULATIONS DU COUPLE DE LA MACHINE SYNCHRONE FONCTIONNANT A FACTEUR DE PUISSANCE UNITAIRE