[PDF] Condensation Induced Water Hammer In Steam Supply System U - eBooks Review

Condensation Induced Water Hammer In Steam Supply System U


Condensation Induced Water Hammer In Steam Supply System U
DOWNLOAD

Download Condensation Induced Water Hammer In Steam Supply System U PDF/ePub or read online books in Mobi eBooks. Click Download or Read Online button to get Condensation Induced Water Hammer In Steam Supply System U book now. This website allows unlimited access to, at the time of writing, more than 1.5 million titles, including hundreds of thousands of titles in various foreign languages. If the content not found or just blank you must refresh this page





Condensation Induced Water Hammer In Steam Supply System U


Condensation Induced Water Hammer In Steam Supply System U
DOWNLOAD
Author : G. A. Antakl
language : en
Publisher:
Release Date : 1995

Condensation Induced Water Hammer In Steam Supply System U written by G. A. Antakl and has been published by this book supported file pdf, txt, epub, kindle and other format this book has been release on 1995 with categories.




Condensate Induced Water Hammer In A Steam Distribution System Results In Fatality


Condensate Induced Water Hammer In A Steam Distribution System Results In Fatality
DOWNLOAD
Author :
language : en
Publisher:
Release Date : 1996

Condensate Induced Water Hammer In A Steam Distribution System Results In Fatality written by and has been published by this book supported file pdf, txt, epub, kindle and other format this book has been release on 1996 with categories.


Water hammer event s in steam distribution piping interrupt service and have the potential to cause serious injury and property damage. Conditions of condensation induced water hammer are discussed and recommendations aimed to improve safety of steam systems are presented. Condensate induced water hammer events at Hanford, a DOE facility, are examined.



Safety Considerations For Condensation Induced Water Hammer In Steam Piping System


Safety Considerations For Condensation Induced Water Hammer In Steam Piping System
DOWNLOAD
Author :
language : en
Publisher:
Release Date : 1994

Safety Considerations For Condensation Induced Water Hammer In Steam Piping System written by and has been published by this book supported file pdf, txt, epub, kindle and other format this book has been release on 1994 with categories.


The phenomenon of condensation induced water hammer may occur when subcooled water and steam interact and form a water slug by rapid steam condensation, and the slug is accelerated through the piping by the full system pressure. The sudden deceleration of the slug by existing liquid in the system, or by any part of the piping system can produce large pressure pulses, that by themselves or in combination with other loads, can rupture the piping system. This paper describes the results of a study on condensation induced water hammer in a specific piping geometry, and lists recommendations that when implemented will prevent piping system failure.



An Evaluation Of Condensation Induced Water Hammer In Preheat Steam Generators


An Evaluation Of Condensation Induced Water Hammer In Preheat Steam Generators
DOWNLOAD
Author : Pradip Saha
language : en
Publisher:
Release Date : 1980

An Evaluation Of Condensation Induced Water Hammer In Preheat Steam Generators written by Pradip Saha and has been published by this book supported file pdf, txt, epub, kindle and other format this book has been release on 1980 with Nuclear pressure vessels categories.




Geschichte Und Ergebnisse Der Zentralen Amtlichen Statistik In Oesterreich


Geschichte Und Ergebnisse Der Zentralen Amtlichen Statistik In Oesterreich
DOWNLOAD
Author :
language : en
Publisher:
Release Date : 1979

Geschichte Und Ergebnisse Der Zentralen Amtlichen Statistik In Oesterreich written by and has been published by this book supported file pdf, txt, epub, kindle and other format this book has been release on 1979 with categories.




Condensation Induced Water Hammer In Steam Generators


Condensation Induced Water Hammer In Steam Generators
DOWNLOAD
Author :
language : en
Publisher:
Release Date : 1979

Condensation Induced Water Hammer In Steam Generators written by and has been published by this book supported file pdf, txt, epub, kindle and other format this book has been release on 1979 with categories.


The case of condensation induced water hammer in nuclear steam generators is summarized, including both feed ring-type and economizer-type geometries. A slug impact model is described and used to demonstrate the parametric dependence of the impact pressures on heat transfer rates, initial pressures, and relative initial slug and void lengths. The results of the parametric study are related also to the economizer geometry and a suggested alternative model is presented. The importance of concerns regarding attenuation of shocks in two-phase media is delineated, and a simple experiment is described which was used to determine negligible attenuation within the accuracy of the experiment for void fractions up to over 30% in bubbly and slug flows.



Evaluation Of Condensation Induced Water Hammer In Preheat Steam Generators


Evaluation Of Condensation Induced Water Hammer In Preheat Steam Generators
DOWNLOAD
Author :
language : en
Publisher:
Release Date : 1980

Evaluation Of Condensation Induced Water Hammer In Preheat Steam Generators written by and has been published by this book supported file pdf, txt, epub, kindle and other format this book has been release on 1980 with categories.


A review of Westinghouse 1/8-scale water hammer tests and data analysis was carried out. BNL has concluded that water hammers occurred in the feedwater line during many of the 1/8-scale tests. These events were probably caused by steam bubble entrapment and collapse in the partially-filled feedwater line. Recorded vessel pressure pulse activity under two-phase operating conditions was rare and, in those cases where pulses were recorded, the pressure pulse amplitudes were small. Either void collapse water hammers are unlikely events under these two-phase conditions, or events that did occur were attenuated in magnitude by the two-phase medium and internal structures before the pulse reached the pressure transducer. Pressure pulse attenuation in two-phase air-water media was studied experimentally at BNL. It was found that no significant attenuation could be detected in two-phase flows over distances of approximately 1 to 2 ft. The effects of internals, however, were not considered. The Westinghouse scaling laws have also been critically reviewed. An independent BNL analysis was carried out to verify the Westinghouse scaling laws. It has been found that the present state-of-the-art on the condensation heat transfer and the mechanism of vapor cavity formation precludes us from deriving any credible scaling criteria. However, it was found that under certain operating conditions the condensation-induced void collapse could be an oscillatory process. This may partially explain the apparent randomness of the water hammer phenomenon seen in most experimental studies.



Steam Condensation Induced Water Hammer In A Vertical Up Fill Configuration Within An Integral Test Facility Experiments And Computational Simulations


Steam Condensation Induced Water Hammer In A Vertical Up Fill Configuration Within An Integral Test Facility Experiments And Computational Simulations
DOWNLOAD
Author : Stefan Dirndorfer
language : en
Publisher:
Release Date : 2017

Steam Condensation Induced Water Hammer In A Vertical Up Fill Configuration Within An Integral Test Facility Experiments And Computational Simulations written by Stefan Dirndorfer and has been published by this book supported file pdf, txt, epub, kindle and other format this book has been release on 2017 with categories.




Using Stratified Flow To Mitigate Condensation Induced Water Hammer


Using Stratified Flow To Mitigate Condensation Induced Water Hammer
DOWNLOAD
Author : Richard Raphael Schultz
language : en
Publisher:
Release Date : 2010

Using Stratified Flow To Mitigate Condensation Induced Water Hammer written by Richard Raphael Schultz and has been published by this book supported file pdf, txt, epub, kindle and other format this book has been release on 2010 with Dissertations, Academic categories.


Research accomplished to determine whether stratified flow may be used to prevent the occurrence of condensation-induced water hammer (CIWH) in a horizontal pipe partially-filled with subcooled flowing water in the presence of saturated steam is described. Earlier researchers have shown that CIWH will readily occur in a horizontal pipe under such conditions when the void fraction is greater than 0.2 and the water is subcooled in excess of 20 °C. Such conditions have been shown to occur in advanced reactor systems when using passive emergency core cooling systems designed to ensure the core remains covered. Flow rates from passive emergency core cooling systems, which do not use pumps, are dictated by buoyancy-driven flows that are governed by liquid density-gradients. Research completed at the Idaho State University Thermal-Fluids Laboratory using a steam-water loop and an air-water test apparatus has shown that CIWH may be avoided even with highly subcooled water flowing in the presence of saturated steam if the subcooled flow water is segregated from the saturated steam using a saturated water stratified layer. This research report summarizes: (a) the theory and data that underlie the occurrence of CIWH, (b) an approach for preventing CIWH at flow conditions where CIWH would normally occur, (c) the theory that support the approach, (d) the experiments performed to produce data that support the approach, and (e) how to define the operational envelope where operation is allowed within a horizontal pipe partially-filled with highly-subcooled water in the presence of saturated steam. Because passively-cooled systems in light water reactors are generally configured to provide emergency core cooling flow to a reactor system via horizontal pipes with length-to-diameter (L/D) ratios ranging from 6 to 70, where the pipes are plumbed normal to the reactor vessel downcomer region, the experimental configuration consisted of a horizontal pipe with appropriate LID ranges plumbed to a reservoir that simulated the reactor vessel downcomer. Research indicates that the subcooled water flow rate must be designed to ensure the flow rate is laminar and the steam velocities, moving in the counter-current direction to the subcooled water flow, must be less than a critical value.



Steam Condensation Induced Waterhammer In Vertical Up Fill Configuration


Steam Condensation Induced Waterhammer In Vertical Up Fill Configuration
DOWNLOAD
Author : Richard Marlow (M.Eng.)
language : en
Publisher:
Release Date : 1994

Steam Condensation Induced Waterhammer In Vertical Up Fill Configuration written by Richard Marlow (M.Eng.) and has been published by this book supported file pdf, txt, epub, kindle and other format this book has been release on 1994 with Pipe categories.